Sunthai
Stainless Steel
tri-clamp non return valve for Data Center Liquid Cooling
Size | 1"-4", DN25-DN100 |
Surface Treatment | Ra ≤0.8 μm |
Seal | NBR, PTFE, Viton, EPDM |
Max Pressure | 10bar, 145psi |
Working Temperature | -10℃ to 130℃ |
Reverse flow in liquid cooling pipelines can cause severe risks: pump damage, coolant backflow, air entrapment and uneven cooling distribution for GPU servers. Our tri-clamp non-return check valve is specially engineered for 24/7 data center liquid cooling infrastructure. It allows one-way coolant flow, prevents backflow effectively, maintains stable circulation of CDU manifolds, cold plate loops and immersion cooling pipelines, with low pressure drop to help optimize your system PUE.
Core Advantages for Liquid Cooling Projects
Reliable One-Way Flow & Backflow Prevention
Spring-assisted non-return structure instantly closes to block reverse coolant flow once the system stops or pressure fluctuates. It protects circulation pumps, avoids air entering closed cooling loops and eliminates the risk of uneven cooling for high-density AI accelerators and server cold plates.
Low Pressure Drop Design, Optimize Cooling System PUE
Streamlined internal flow channel minimizes flow resistance. Compared with traditional swing check valves, it brings less head loss, reduces pump power consumption and supports energy-efficient operation for large-scale data center liquid cooling loops.
Ultra-Clean Inner Surface & Coolant Compatibility
Valve body SS304 / SS316L, mirror polished internal surface Ra ≤0.8μm, no dead zones, no particle shedding. Seal options include EPDM, FKM(Viton), PTFE, fully compatible with DI deionized water, ethylene glycol mixture and dielectric immersion coolant, preventing microchannel clogging of cold plates.
Fast Tri-Clamp Connection, Easy Installation & Inspection
Tri-clamp quick assembly design, no welding required for installation and disassembly. It fits perfectly with standard sanitary stainless piping, convenient for on-site inspection, cleaning and replacement in compact CDU manifold and rack limited space.
Stable Performance for Continuous 24/7 Operation
Precision spring and sealing assembly for repeated cycling. Suitable for long-running closed liquid cooling circuits in hyperscale data centers, HPC and energy storage cooling systems.
Applications
AI GPU Cold Plate Direct Liquid Cooling Loops
CDU (Coolant Distribution Unit) Manifold Branch Lines
Immersion Liquid Cooling Tank Circulation Pipes
HPC High Performance Computing Cooling Systems
Energy Storage Battery Liquid Cooling Pipeline
Secondary Cooling Circuits for Server Racks
Chiller & Pump Outlet Anti-Backflow Protection
Our engineers can help you select the correct spring rating and seal material according to your coolant type, flow rate and working pressure.
Send your technical drawing or project parameters for quotation and sample arrangement.